DTC Advanced Diagnostics: SRS related DTCs
SRS Related DTCs
NOTE
Always check "How to troubleshoot the SRS system" and proceed along each "DTC Troubleshooting" procedure.
Make sure the 12 volt battery is fully charged. If not, the results of tests may not be accurate.
The SRS indicator will turn on when the battery voltage becomes below 10 volts.
The possible causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

DTC B0001-11: Short to Ground in the Driver’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the driver’s airbag 1st inflator (LA1+, LA1- lines)
Driver’s airbag internal failure (Driver’s airbag 1st inflator)
SRS unit internal failure

DTC B0001-12: Short to Power in the Driver’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the driver’s airbag 1st inflator (LA1+, LA1- lines)
Driver’s airbag internal failure (Driver’s airbag 1st inflator)
SRS unit internal failure

DTC B0001-13: Open or Increased Resistance in the Driver’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s airbag 1st inflator (LA1+, LA1- lines)
Driver’s airbag internal failure (Driver’s airbag 1st inflator)
SRS unit internal failure

DTC B0001-1A: Decreased Resistance in the Driver’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the driver’s airbag 1st inflator (LA1+, LA1- lines)
Driver’s airbag internal failure (Driver’s airbag 1st inflator)
SRS unit internal failure

DTC B0001-2B: Short to Another Wire Harness in the Driver’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s airbag 1st inflator (LA1+ line to LA2+ line, LA1- line to LA2- line)
Driver’s airbag internal failure (Driver’s airbag 1st inflator)
SRS unit internal failure

DTC B0002-11: Short to Ground in the Driver’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the driver’s airbag 2nd inflator (LA2+, LA2- lines)
Driver’s airbag internal failure (Driver’s airbag 2nd inflator)
SRS unit internal failure

DTC B0002-12: Short to Power in the Driver’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the driver’s airbag 2nd inflator (LA2+, LA2- lines)
Driver’s airbag internal failure (Driver’s airbag 2nd inflator)
SRS unit internal failure

DTC B0002-13: Open or Increased Resistance in the Driver’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s airbag 2nd inflator (LA2+, LA2- lines)
Driver’s airbag internal failure (Driver’s airbag 2nd inflator)
SRS unit internal failure

DTC B0002-1A: Decreased Resistance in the Driver’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the driver’s airbag 2nd inflator (LA2+, LA2- lines)
Driver’s airbag internal failure (Driver’s airbag 2nd inflator)
SRS unit internal failure

DTC B0002-2B: Short to Another Wire Harness in the Driver’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s airbag 2nd inflator (LA1+ line to LA2+ line, LA1- line to LA2- line)
Driver’s airbag internal failure (Driver’s airbag 2nd inflator)
SRS unit internal failure

DTC B0010-11: Short to Ground in the Front Passenger’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the front passenger’s airbag 1st inflator (RA1+, RA1- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 1st inflator)
SRS unit internal failure

DTC B0010-12: Short to Power in the Front Passenger’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the front passenger’s airbag 1st inflator (RA1+, RA1- lines)
SRS unit internal failure

DTC B0010-13: Open or Increased Resistance in the Front Passenger’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the front passenger’s airbag 1st inflator (RA1+, RA1- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 1st inflator)
SRS unit internal failure

DTC B0010-1A: Decreased Resistance in the Front Passenger’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the front passenger’s airbag 1st inflator (RA1+, RA1- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 1st inflator)
SRS unit internal failure

DTC B0010-2B: Short to Another Wire Harness in the Front Passenger’s Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the front passenger’s airbag 1st inflator (RA1+, RA1- lines)
SRS unit internal failure

DTC B0011-11: Short to Ground in the Front Passenger’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the front passenger’s airbag 2nd inflator (RA2+, RA2- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 2nd inflator)
SRS unit internal failure

DTC B0011-12: Short to Power in the Front Passenger’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the front passenger’s airbag 2nd inflator (RA2+, RA2- lines)
SRS unit internal failure

DTC B0011-13: Open or Increased Resistance in the Front Passenger’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the front passenger’s airbag 2nd inflator (RA2+, RA2- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 2nd inflator)
SRS unit internal failure

DTC B0011-1A: Decreased Resistance in the Front Passenger’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the front passenger’s airbag 2nd inflator (RA2+, RA2- lines)
Front passenger’s airbag internal failure (Front passenger’s airbag 2nd inflator)
SRS unit internal failure

DTC B0011-2B: Short to Another Wire Harness in the Front Passenger’s Airbag 2nd Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the front passenger’s airbag 2nd inflator (RA2+, RA2- lines)
SRS unit internal failure

DTC B0020-11: Short to Ground in the Driver’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the driver’s side airbag inflator (LSA+, LSA- lines)
Driver’s side airbag internal failure (Driver’s side airbag inflator)
SRS unit internal failure

DTC B0020-12: Short to Power in the Driver’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the driver’s side airbag inflator (LSA+, LSA- lines)
SRS unit internal failure

DTC B0020-13: Open or Increased Resistance in the Driver’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s side airbag inflator (LSA+, LSA- lines)
Driver’s side airbag internal failure (Driver’s side airbag inflator)
SRS unit internal failure

DTC B0020-1A: Decreased Resistance in the Driver’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the driver’s side airbag inflator (LSA+, LSA- lines)
Driver’s side airbag internal failure (Driver’s side airbag inflator)
SRS unit internal failure

DTC B0020-2B: Short to Another Wire Harness in the Driver’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s side airbag inflator (LSA+, LSA- lines)
SRS unit internal failure

DTC B0021-11: Short to Ground in the Left Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the left side curtain airbag inflator (LCA+, LCA- lines)
Left side curtain airbag internal failure (Left side curtain airbag inflator)
SRS unit internal failure

DTC B0021-12: Short to Power in the Left Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the left side curtain airbag inflator (LCA+, LCA- lines)
SRS unit internal failure

DTC B0021-13: Open or Increased Resistance in the Left Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the left side curtain airbag inflator (LCA+, LCA- lines)
Left side curtain airbag internal failure (Left side curtain airbag inflator)
SRS unit internal failure

DTC B0021-1A: Decreased Resistance in the Left Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the left side curtain airbag inflator (LCA+, LCA- lines)
Left side curtain airbag internal failure (Left side curtain airbag inflator)
SRS unit internal failure

DTC B0021-2B: Short to Another Wire Harness in the Left Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the left side curtain airbag inflator (LCA+, LCA- lines)
SRS unit internal failure

DTC B0028-11: Short to Ground in the Front Passenger’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the front passenger’s side airbag inflator (RSA+, RSA- lines)
Front passenger’s side airbag internal failure (Front passenger’s side airbag inflator)
SRS unit internal failure

DTC B0028-12: Short to Power in the Front Passenger’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the front passenger’s side airbag inflator (RSA+, RSA- lines)
SRS unit internal failure

DTC B0028-13: Open or Increased Resistance in the Front Passenger’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the front passenger’s side airbag inflator (RSA+, RSA- lines)
Front passenger’s side airbag internal failure (Front passenger’s side airbag inflator)
SRS unit internal failure

DTC B0028-1A: Decreased Resistance in the Front Passenger’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the front passenger’s side airbag inflator (RSA+, RSA- lines)
Front passenger’s side airbag internal failure (Front passenger’s side airbag inflator)
SRS unit internal failure

DTC B0028-2B: Short to Another Wire Harness in the Front Passenger’s Side Airbag Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the front passenger’s side airbag inflator (RSA+, RSA- lines)
SRS unit internal failure

DTC B0029-11: Short to Ground in the Right Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the right side curtain airbag inflator (RCA+, RCA- lines)
Right side curtain airbag internal failure (Right side curtain airbag inflator)
SRS unit internal failure

DTC B0029-12: Short to Power in the Right Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the right side curtain airbag inflator (RCA+, RCA- lines)
SRS unit internal failure

DTC B0029-13: Open or Increased Resistance in the Right Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the right side curtain airbag inflator (RCA+, RCA- lines)
Right side curtain airbag internal failure (Right side curtain airbag inflator)
SRS unit internal failure

DTC B0029-1A: Decreased Resistance in the Right Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the right side curtain airbag inflator (RCA+, RCA- lines)
Right side curtain airbag internal failure (Right side curtain airbag inflator)
SRS unit internal failure

DTC B0029-2B: Short to Another Wire Harness in the Right Side Curtain Airbag 1st Inflator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the right side curtain airbag inflator (RCA+, RCA- lines)
SRS unit internal failure

DTC B0050-11: Short or Decreased Resistance in the Driver’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground or Short to power between the SRS unit and the driver’s seat belt buckle switch (FLBC line)
Driver’s seat belt buckle assembly internal failure (Driver’s seat belt buckle switch)
SRS unit internal failure

DTC B0050-13: Open or Increased Resistance in the Driver’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s seat belt buckle switch (FLBC line)
Open or Poor connection between the driver’s seat belt buckle switch and the body ground (GND line)
Driver’s seat belt buckle assembly internal failure (Driver’s seat belt buckle switch)
SRS unit internal failure

DTC B0050-2B: Short to Another Wire Harness in the Driver’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s seat belt buckle switch (FLBC line)
Driver’s seat belt buckle assembly internal failure (Driver’s seat belt buckle switch)

DTC B0052-11: Short or Decreased Resistance in the Front Passenger’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground or Short to power between the SRS unit and the front passenger’s seat belt buckle switch (FRBC line)
Front passenger’s seat belt buckle assembly internal failure (Front passenger’s seat belt buckle switch)
SRS unit internal failure

DTC B0052-13: Open or Increased Resistance in the Front Passenger’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the front passenger’s seat belt buckle switch (FRBC line)
Open or Poor connection between the front passenger’s seat belt buckle switch and the body ground (GND line)
Front passenger’s seat belt buckle assembly internal failure (Front passenger’s seat belt buckle switch)
SRS unit internal failure

DTC B0052-2B: Short to Another Wire Harness in the Front Passenger’s Seat Belt Buckle Switch
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the front passenger’s seat belt buckle switch (FRBC line)
Front passenger’s seat belt buckle assembly internal failure (Front passenger’s seat belt buckle switch)

DTC B0070-11: Short to Ground in the Driver’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the driver’s seat belt tensioner (LRP+, LRP- lines)
Driver’s seat belt internal failure (Driver’s seat belt tensioner)
SRS unit internal failure

DTC B0070-12: Short to Power in the Driver’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the driver’s seat belt tensioner (LRP+, LRP- lines)
SRS unit internal failure

DTC B0070-13: Open or Increased Resistance in the Driver’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s seat belt tensioner (LRP+, LRP- lines)
Driver’s seat belt internal failure (Driver’s seat belt tensioner)
SRS unit internal failure

DTC B0070-1A: Decreased Resistance in the Driver’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the driver’s seat belt tensioner (LRP+, LRP- lines)
Driver’s seat belt internal failure (Driver’s seat belt tensioner)
SRS unit internal failure

DTC B0070-2B: Short to Another Wire Harness in the Driver’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s seat belt tensioner (LRP+, LRP- lines)
SRS unit internal failure

DTC B0072-11: Short to Ground in the Front Passenger’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the front passenger’s seat belt tensioner (RRP+, RRP- lines)
Front passenger’s seat belt internal failure (Front passenger’s seat belt tensioner)
SRS unit internal failure

DTC B0072-12: Short to Power in the Front Passenger’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the front passenger’s seat belt tensioner (RRP+, RRP- lines)
SRS unit internal failure

DTC B0072-13: Open or Increased Resistance in the Front Passenger’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the front passenger’s seat belt tensioner (RRP+, RRP- lines)
Front passenger’s seat belt internal failure (Front passenger’s seat belt tensioner)
SRS unit internal failure

DTC B0072-1A: Decreased Resistance in the Front Passenger’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line or Poor connection between the SRS unit and the front passenger’s seat belt tensioner (RRP+, RRP- lines)
Front passenger’s seat belt internal failure (Front passenger’s seat belt tensioner)
SRS unit internal failure

DTC B0072-2B: Short to Another Wire Harness in the Front Passenger’s Seat Belt Tensioner
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the front passenger’s seat belt tensioner (RRP+, RRP- lines)
SRS unit internal failure

DTC B0090-4A: Internal Failure of the Left Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect left front impact sensor installed
Incorrect SRS unit installed
Left front impact sensor internal failure
SRS unit internal failure

DTC B0090-87: No Signal from the Left Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the left front impact sensor (LFS+, LFS- lines)
Left front impact sensor internal failure
SRS unit internal failure

DTC B0090-92: Internal Failure of the Left Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Left front impact sensor internal failure
SRS unit internal failure

DTC B0091-4A: Internal Failure of the Left Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect left side impact sensor (1st) installed
Incorrect SRS unit installed
Left side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0091-87: No Signal from the Left Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the left side impact sensor (1st) (LS1+, LS1- lines)
Left side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0091-92: Internal Failure of the Left Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Left side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0092-4A: Internal Failure of the Left Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect left side impact sensor (2nd) installed
Incorrect SRS unit installed
Left side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0092-87: No Signal from the Left Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the left side impact sensor (2nd) (LS2+, LS2- lines)
Left side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0092-92: Internal Failure of the Left Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Left side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0093-4A: Internal Failure of the Left Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect left side impact sensor (3rd) installed
Incorrect SRS unit installed
Left side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B0093-87: No Signal from the Left Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the left side impact sensor (3rd) (LS3+, LS3- lines)
Left side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B0093-92: Internal Failure of the Left Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Left side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B0095-4A: Internal Failure of the Right Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect right front impact sensor installed
Incorrect SRS unit installed
Right front impact sensor internal failure
SRS unit internal failure

DTC B0095-87: No Signal from the Right Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the right front impact sensor (RFS+, RFS- lines)
Right front impact sensor internal failure
SRS unit internal failure

DTC B0095-92: Internal Failure of the Right Front Impact Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Right front impact sensor internal failure
SRS unit internal failure

DTC B0096-4A: Internal Failure of the Right Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect right side impact sensor (1st) installed
Incorrect SRS unit installed
Right side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0096-87: No Signal from the Right Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the right side impact sensor (1st) (RS1+, RS1- lines)
Right side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0096-92: Internal Failure of the Right Side Impact Sensor (1st)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Right side impact sensor (1st) internal failure
SRS unit internal failure

DTC B0097-4A: Internal Failure of the Right Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect right side impact sensor (2nd) installed
Incorrect SRS unit installed
Right side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0097-87: No Signal from the Right Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the right side impact sensor (2nd) (RS2+, RS2- lines)
Right side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0097-92: Internal Failure of the Right Side Impact Sensor (2nd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Right side impact sensor (2nd) internal failure
SRS unit internal failure

DTC B0098-4A: Internal Failure of the Right Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect right side impact sensor (3rd) installed
Incorrect SRS unit installed
Right side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B0098-87: No Signal from the Right Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the right side impact sensor (3rd) (RS3+, RS3- lines)
Right side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B0098-92: Internal Failure of the Right Side Impact Sensor (3rd)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Right side impact sensor (3rd) internal failure
SRS unit internal failure

DTC B00A0-54: Front Passenger's Weight Sensor Not Calibrated
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's weight sensor not initialized
Front passenger's weight sensor improper initialization
Front passenger's weight sensor internal failure

DTC B00A0-87: Lost communication with the SWS Unit
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the front passenger’s weight sensor unit (ODS/SWS ODUS line)
Open or Poor connection between the front passenger’s weight sensor unit and the under-dash fuse/relay box (SWS POW line)
Open or Poor connection between the front passenger’s weight sensor unit and the body ground (SWS GND line)
Blown fuse (Under-dash fuse/relay box No. B6 (7.5A))
Front passenger’s weight sensor unit internal failure
SRS unit internal failure

DTC B00B5-11: Short or Decreased Resistance in the Driver’s Seat Position Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to ground between the SRS unit and the driver’s seat position sensor (SS+/LSPS lines)
Driver’s seat position sensor internal failure
SRS unit internal failure

DTC B00B5-13: Open or Increased Resistance in the Driver’s Seat Position Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Poor connection between the SRS unit and the driver’s seat position sensor (SS+/LSPS lines)
Open or Poor connection between the driver’s seat position sensor and the body ground (GND LSPS lines)
Driver’s seat position sensor internal failure
SRS unit internal failure

DTC B00B5-2B: Short to Another Wire Harness in the Driver’s Seat Position Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to another line between the SRS unit and the driver’s seat position sensor (SS+/LSPS lines)
Driver’s seat position sensor internal failure
SRS unit internal failure

DTC B00C0-16: Internal Failure of the Front Passenger's Weight Sensor (front inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front inner side)) (4-door)

DTC B00C0-4A: Different Supplier ID/Function ID of the Front Passenger's Weight Sensor (front inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front inner side)) (4-door)

DTC B00C0-54: Different Serial ID of the Front Passenger's Weight Sensor (front inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front inner side)) (4-door)

DTC B00C0-87: No Signal From the Front Passenger's Weight Sensor (front inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the front passenger's weight sensor (front inner side) (SWS+, SWS-, SWSS lines)
Short to power between the SRS unit and the front passenger's weight sensor (front inner side) (SWSS line)
Short to ground between the SRS unit and the front passenger's weight sensor (front inner side) (SWSS line)
Short to another line between the SRS unit and the front passenger's weight sensor (front inner side) (SWSS, SWS- lines)
Short to another line between the SRS unit and the front passenger's weight sensor (front inner side) (SWSS, SWS+ lines)
SRS unit internal failure

DTC B00C0-96: Internal Failure of the Front Passenger's Weight Sensor (front inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front inner side)) (4-door)

DTC B00C1-16: Internal Failure of the Front Passenger's Weight Sensor (front outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front outer side)) (4-door)

DTC B00C1-4A: Different Supplier ID/Function ID of the Front Passenger's Weight Sensor (front outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front outer side)) (4-door)

DTC B00C1-54: Different Serial ID of the Front Passenger's Weight Sensor (front outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front outer side)) (4-door)

DTC B00C1-87: No Signal From the Front Passenger's Weight Sensor (front outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the front passenger's weight sensor (front outer side) (SWS+, SWS-, SWSS lines)
SRS unit internal failure

DTC B00C1-96: Internal Failure of the Front Passenger's Weight Sensor (front outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (front outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (front outer side)) (4-door)

DTC B00C2-16: Internal Failure of the Front Passenger's Weight Sensor (rear inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear inner side)) (4-door)

DTC B00C2-4A: Different Supplier ID/Function ID of the Front Passenger's Weight Sensor (rear inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear inner side)) (4-door)

DTC B00C2-54: Different Serial ID of the Front Passenger's Weight Sensor (rear inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear inner side)) (4-door)

DTC B00C2-87: No Signal From the Front Passenger's Weight Sensor (rear inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the front passenger's weight sensor (rear inner side) (SWS+, SWS-, SWSS lines)
SRS unit internal failure

DTC B00C2-96: Internal Failure of the Front Passenger's Weight Sensor (rear inner side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear inner side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear inner side)) (4-door)

DTC B00C3-16: Internal Failure of the Front Passenger's Weight Sensor (rear outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear outer side)) (4-door)

DTC B00C3-4A: Different Supplier ID/Function ID of the Front Passenger's Weight Sensor (rear outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear outer side)) (4-door)

DTC B00C3-54: Different Serial ID of the Front Passenger's Weight Sensor (rear outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear outer side)) (4-door)

DTC B00C3-87: No Signal From the Front Passenger's Weight Sensor (rear outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the front passenger's weight sensor (rear outer side) (SWS+, SWS-, SWSS lines)
SRS unit internal failure

DTC B00C3-96: Internal Failure of the Front Passenger's Weight Sensor (rear outer side)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Front passenger's seat frame internal failure (Front passenger's weight sensor (rear outer side)) (2-door)
Front passenger's seat rail internal failure (Front passenger's weight sensor (rear outer side)) (4-door)

DTC B00D5-14: Open or Short to Ground in the Front Passenger’s Airbag Cutoff Indicator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 9 seconds.
Duration
About 9 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open or Short to ground between the SRS unit and the front passenger’s airbag cutoff indicator (OFF PTT line)
Open or Short to ground between the battery and the front passenger’s airbag cutoff indicator
Front passenger’s airbag cutoff indicator internal failure
SRS unit internal failure

DTC B00D5-17: Short to Power in the Front Passenger’s Airbag Cutoff Indicator
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 9 seconds.
Duration
About 9 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Short to power between the SRS unit and the front passenger’s airbag cutoff indicator (OFF PTT line)
Front passenger’s airbag cutoff indicator internal failure
SRS unit internal failure

DTC B2800-49: Internal Failure of the SRS Unit
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure

DTC B2801-49: Internal Failure of the SRS Unit
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure

DTC B2802-49: Internal Failure of the SRS Unit
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure

DTC B280A-4A: Internal Failure of the Rear Safing Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Incorrect rear safing sensor installed
Incorrect SRS unit installed
Rear safing sensor internal failure
SRS unit internal failure

DTC B280A-87: No Signal from the Rear Safing Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open, Short to another line, Short to ground, Short to power, or Poor connection between the SRS unit and the rear safing sensor (SSS+, SSS- lines)
Rear safing sensor internal failure
SRS unit internal failure

DTC B280A-92: Internal Failure of the Rear Safing Sensor
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Rear safing sensor internal failure
SRS unit internal failure

DTC B2840-13: SRS Unit Connector A Not Properly Installed
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Poor connection between the SRS unit and connector A
SRS unit internal failure

DTC B2841-13: SRS Unit Connector B Not Properly Installed
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Poor connection between the SRS unit and connector B
SRS unit internal failure

DTC U0101-00: Lost Communication with the PCM (PGM-FI system)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the PCM (F-CAN_H, F-CAN_L lines)
SRS unit internal failure

DTC U0155-00: Lost Communication with the Gauge Control Module
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the gauge control module (F-CAN_H, F-CAN_L lines)
Gauge control module internal failure
SRS unit internal failure

DTC U3000-49: Internal Failure of the SRS Unit
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure

DTC U3000-51: SRS Unit Programming Error
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure

DTC U3006-13: Faulty Power Supply (VA line)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the under-dash fuse/relay box (VA line)
Blown fuse (Under-dash fuse/relay box No. B6 (7.5A))
SRS unit internal failure

DTC U3007-13: Faulty Power Supply (VB line)
Confirmation Procedure
Basic Condition:
Battery voltage 10 - 16 V

Operating Condition:
1.
Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
Open between the SRS unit and the under-dash fuse/relay box (VB line)
Blown fuse (Under-dash fuse/relay box No. B24 (10A))
SRS unit internal failure