DTC Advanced Diagnostics: P0125
DTC P0125:Engine Coolant Temperature (ECT) Sensor 1 Malfunction/Slow Response (Engine Type: J35Y1, J35Y2)

General Description

The powertrain control module (PCM) supplies voltage to the engine coolant temperature signal circuit (about 5 V) through a pull-up resistor. As the engine coolant cools, the engine coolant temperature (ECT) sensor 1 resistance increases, and the PCM detects a high signal voltage. As the engine coolant warms, the ECT sensor 1 resistance decreases, and the PCM detects a low signal voltage. If the ECT sensor 1 output voltage does not reach a specified temperature at which closed loop control for stoichiometric air/fuel ratio starts within a set time, depending on the initial engine coolant temperature after starting the engine, the PCM detects a malfunction and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status
Execution
Once per driving cycle
Sequence
None
Duration
20 minutes or less
DTC Type
Two drive cycles, MIL on
OBD Status
PASSED/FAILED/NOT COMPLETED (STILL TESTING)

Enable Conditions
Condition
Minimum
Maximum
Initial engine coolant temperature [ECT SENSOR 1]
10 °F (-12 °C)
Fuel feedback
Other than during fuel cut-off operation
No active DTCs set (prevents monitor from running)*1
P0101, P0102, P0103, P0107, P0108, P0111, P0112, P0113, P0117, P0118, P0134, P0135, P0154, P0155, P0171, P0172, P0174, P0175, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0351, P0352, P0353, P0354, P0355, P0356, P0401, P0404, P0443, P0496, P0497, P0506, P0507, P0627, P1128, P1129, P1172, P1174, P145C, P2195, P2197, P2227, P2228, P2229, P2237, P2238, P2240, P2241, P2243, P2245, P2247, P2249, P2251, P2252, P2254, P2255, P2279, P2413, P2646, P2647, P2648, P2649, P2652, P2654, P2656, P2657, P2658, P2659
No active DTCs set (prevents monitor from running)*2
P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0134, P0135, P0154, P0171, P0172, P0174, P0175, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0351, P0352, P0353, P0354, P0355, P0356, P0401, P0404, P0443, P0496, P0497, P0506, P0507, P0627, P1128, P1129, P1172, P1174, P145C, P2195, P2197, P2227, P2228, P2229, P2237, P2238, P2243, P2245, P2251, P2252, P2279, P2413, P2627, P2628, P2646, P2647, P2648, P2649, P2652, P2654, P2656, P2657, P2658, P2659
No active DTCs set (prevents monitor from running)*3
P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0122, P0123, P0134, P0135, P0154, P0171, P0172, P0174, P0175, P0201, P0202, P0203, P0204, P0205, P0206, P0222, P0223, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0340, P0344, P0351, P0352, P0353, P0354, P0355, P0356, P0401, P0404, P0443, P0506, P0507, P060A, P0627, P1172, P1174, P1659, P2101, P2118, P2122, P2123, P2127, P2128, P2135, P2138, P2176, P2195, P2197, P2228, P2229, P2237, P2238, P2243, P2245, P2251, P2252, P2279, P2413, P2627, P2628, P2646, P2647, P2648, P2649, P2652, P2654, P2656, P2657, P2658, P2659
*1: 2013 model

*2: 2014, 2015 models

*3: 2016 model on and after

[ ]: HDS Parameter

Malfunction Threshold
The engine running time before the engine coolant temperature [ECT SENSOR 1] reaches 10 °F (-12 °C), based on the initial engine coolant temperatures [ECT SENSOR 1], is as follows:

Initial engine coolant temperature [ECT SENSOR 1]
Engine running time
-25 °F (-31 °C)
5 minutes or more
10 °F (-12 °C)
1 minute or more

Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
ECT sensor 1 failure
Thermostat stuck open

Confirmation Procedure
Operating Condition
1.
Start the engine under Enable Conditions (see "Initial engine coolant temperature [ECT SENSOR 1]").
2.
Let the engine idle for at least 20 minutes.
With the HDS
None.

Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected during the first drive cycle with the engine coolant temperature and intake air temperature at engine start-up within the specified temperature range, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle with the engine coolant temperature and intake air temperature at engine start-up within the specified temperature range, the MIL comes on and a Confirmed DTC and the freeze data are stored.

Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the battery.