DTC Advanced Diagnostics: P0617
DTC P0617:Starter Cut Relay Diagnosis Circuit High Voltage (Engine Type: K24W1)

General Description

The starter control system prevents the starter from accidentally activating when the shift lever is not in the P or N position (CVT) or the clutch pedal is released (M/T), or when the engine is running. If the engine start/stop button is pressed mistakenly while the shift lever is not in P or N position (CVT) or the clutch pedal is released (M/T) or while the engine is running, the powertrain control module (PCM) will stop power to the starter cut relays. In this system, two starter cut relays are connected in series (starter cut relay 1 circuit, starter cut relay 2 circuit) to prevent the starter from running continuously due to a starter cut relay malfunction. Also a diagnosis line (ST RLY 1 TO 2) is connected to monitor the voltage between the starter cut relay 1 circuit and starter cut relay 2 circuit. Based on the diagnosis line signals, the PCM detects an OPEN malfunction of diagnosis line, an ON malfunction of starter cut relay 1 circuit, and an ON malfunction of starter cut relay 2 circuit. If the voltage of the diagnosis line (ST RLY 1 TO 2) is a specified voltage for a set time when the starter switch (STS) is OFF, the PCM detects an ON malfunction of starter cut relay 1 circuit and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status
Execution
Continuous
Sequence
None
Duration
5 seconds or more
DTC Type
One drive cycle, MIL off
OBD Status
PASSED/FAILED/NOT COMPLETED (STILL TESTING)

Enable Conditions
Condition
 
Engine start/stop button
ON mode

Malfunction Threshold
The diagnosis line (ST RLY 1 TO 2) input voltage [STARTER CUT RELAY] is 4.90 V or more for at least 5 seconds.

[ ]: HDS Parameter

Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
Starter cut relay 1 circuit ON failure
Starter cut relay 1 circuit line short to power
Starter cut relay ST RLY 1 TO 2 line short to power
PCM internal circuit failure

Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected, a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory. The MIL does not come on.

Conditions for clearing the DTC
The Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the battery.