DTC Advanced Diagnostics: P2422
DTC P2422:Evaporative Emission (EVAP) Canister Vent Shut Valve Stuck Closed Malfunction General Description
The fuel tank pressure (FTP) sensor output is near atmospheric pressure (0 kPa (0 mmHg, 0 inHg)) before purge starts since the evaporative emission (EVAP) canister vent shut valve is normally open (to the atmosphere). The sensor indicates a negative pressure value (vacuum) while purging. When the FTP sensor indicates vacuum after the engine starts, an FTP sensor zero point shift failure or an EVAP canister vent shut valve stuck closed can occur. To prevent these failures, the powertrain control module (PCM) monitors the FTP sensor output after purge starts. The PCM detects a malfunction of the EVAP canister vent shut valve if the output indicates excessive vacuum. However, if the fuel tank internal pressure is below the specified value (excessive vacuum is detected) when starting the engine, the malfunction detection should be done as follows because it is difficult to distinguish between FTP sensor range problem (P1454) and an EVAP canister vent shut valve stuck closed problem (P2422).
Monitor Execution, Sequence, Duration, DTC Type
Enable Conditions
Malfunction Threshold
The output from the FTP sensor [FTP SENSOR] is -4 kPa (-25 mmHg, -1.0 inHg)*, -2 kPa (-10 mmHg, -0.4 inHg)** or less for at least 1.04*, 8.0** seconds. Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
Confirmation Procedure
Operating Condition
With the HDS
None. Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored. Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery. |