DTC Advanced Diagnostics: P0351, P0352, P0353, P0354
DTC P0351:No. 1 Cylinder Ignition Coil Circuit Malfunction DTC P0352:No. 2 Cylinder Ignition Coil Circuit Malfunction DTC P0353:No. 3 Cylinder Ignition Coil Circuit Malfunction DTC P0354:No. 4 Cylinder Ignition Coil Circuit Malfunction General Description
The ignition coil is triggered at the optimum time by the powertrain control module (PCM) ON/OFF command. The PCM detects a malfunction when the engine is running and the return signal does not change for a specified time, the PCM detects a malfunction and stores a DTC. Monitor Execution, Sequence, Duration, DTC Type
Enable Conditions
Malfunction Threshold
The return signal does not change for at least 5 seconds when the ignition coil is triggered. Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
DTC: P0351
DTC: P0352
DTC: P0353
DTC: P0354
Common
Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory. Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery. |