DTC Advanced Diagnostics: P061B
DTC P061B:Powertrain Control Module (PCM) Internal Malfunction (Torque Calculation) General Description
The powertrain control module (PCM) calculates the target torque from the accelerator pedal inputs, external demands, and auxiliary load information, and calculates the allowable torque of up to acceleration state leads to hazardous event for the target torque. Abnormal accelerations are detected by the relations of the target torque, the allowable torque, and the torque estimated from engine output command. There are two methods to detect abnormal accelerations; time judgment method and integration judgment method. If both of the methods are judged abnormal, the PCM detects a malfunction and stores a DTC.
Monitor Execution, Sequence, Duration, DTC Type
Enable Conditions
Malfunction Threshold
Both of the conditions occur:
Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
Confirmation Procedure
Operating Condition
With the HDS
None. Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory. Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery. |