DTC Advanced Diagnostics: P2563
DTC P2563:Turbocharger Wastegate Control Actuator Position Sensor Out of Range General Description
The powertrain control module (PCM) monitors the turbocharger wastegate control actuator position sensor circuit for physical range check. The diagnostic compares the voltages of the turbocharger wastegate control actuator position sensor read at the closed and open positions of the turbocharger valve with their respective calibrated threshold values. If the turbocharger wastegate control actuator position sensor output voltage is a specified value for a specified time, the PCM detects a malfunction and stores a DTC. Monitor Execution, Sequence, Duration, DTC Type
Enable Conditions
Malfunction Threshold
Either of the conditions continues for at least 0.14 second.
[ ]: HDS Parameter Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored. Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command. |