Power Window Master Switch Connector for Inputs and Outputs

Terminal number
Terminal name
Description
Signal
1
P/W DR MTR DOWN
Drives driver's power window motor
With driver's power window motor DOWN operation: about battery voltage
If none of above conditions are met: less than 0.2 V
2
P/W DR MTR UP
Drives driver's power window motor
With driver's power window motor UP operation: about battery voltage
If none of above conditions are met: less than 0.2 V
3
GND
Ground for power window master switch
Less than 0.2 V at all times
4
+B P/W DR
Power source for door multiplex control unit
About battery voltage at all times
5
Not used
???
???
6
Not used
???
???
7
DR KEY CLY LOCK
Detects DR KEY CYL LOCK signal
With driver's door key cylinder switch UNLOCK: about battery voltage
With driver's door key cylinder switch LOCK: less than 0.2 V
8
DR KEY CLY UNLOCK
Detects DR KEY CYL UNLOCK signal
With driver's door key cylinder switch LOCK: about battery voltage
With driver's door key cylinder switch UNLOCK: less than 0.2 V
9
TRUNK OPEN SW(INTR)
Detects TRUNK OPEN SW (INTR) signal
With trunk lid opener switch ON: less than 0.2 V
With trunk lid opener switch OFF: about battery voltage
10
MIRROR R COM
Detects MIRROR R COM signal
With vehicle in ON mode and power mirror DOWN or LEFT function: about battery voltage
11
MIRROR R LR
Detects MIRROR R LR signal
With vehicle in ON mode and power mirror DOWN or RIGHT function: about battery voltage
12
MIRROR UD
Detects MIRROR UD signal
With vehicle in ON mode and power mirror UP or LEFT function: about battery voltage
13*1
P/W RR L SW RLY UP
Drives left rear power window motor
With left rear power window moving to UP using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
14*1
P/W RR L SW RLY DOWN
Drives left rear power window motor
With left rear power window moving to DOWN using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
15*2
H/MIRROR
Outputs H/MIRROR signal
With mirror defogger ON: about battery voltage
16
Not used
???
???
17
Not used
???
???
18
IG2 A/C
IG2 power source
With vehicle in ON mode: about battery voltage
19
Not used
???
???
20
DR SILCON UNLOCK
Detects DR SILCON UNLOCK signal
With driver's door lock knob switch LOCK: about battery voltage
With driver's door lock knob switch UNLOCK: less than 0.2 V
21
DR SILCON LOCK
Detects DR SILCON LOCK signal
With driver's door lock knob switch UNLOCK: about battery voltage
With driver's door lock knob switch LOCK: less than 0.2 V
22
Not used
???
???
23
Not used
???
???
24
Not used
???
???
25*1
P/W RR R SW RLY DOWN
Drives right rear power window motor
With right rear power window moving to DOWN using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
26*1
P/W RR R SW RLY UP
Drives right rear power window motor
With right rear power window moving to UP using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
27
Not used
???
???
28
Not used
???
???
29
GND
Ground for power window master switch
Less than 0.2 V at all times
30
P/W SW ILLUMI
Outputs P/W SW ILLUMI signal
With combination light switch PARKING: about battery voltage
With combination light switch OFF: less than 0.2 V
31
B-CAN_L
Communication line
???
32
B-CAN_H
Communication line
???
33
P/W DR MTR PLSA
P/W DR MTR PLSA signal
???
34
P/W DR MTR VCC
Outputs P/W DR MTR VCC signal
With door multiplex control unit is wakeup mode: about battery voltage
With door multiplex control unit is sleep mode: less than 0.2 V
35
P/W DR MTR PLSB
P/W DR MTR PLSB signal
???
36
LIN(P/W)
Communication line
???
37
+B BACK UP
Power source for power window master switch
About battery voltage at all times
*1: 4-door
*2: With mirror defogger