Ignition Switch Test
SRS components are located in this area. Review the
SRS component locations
and the
precautions and procedures
before doing repairs or service.
1.
12 Volt Battery Terminal - Disconnect
2.
Column Covers - Remove
3.
Ignition Switch - Test
1.
Disconnect the connector (A).
2.
Check for continuity between the terminals in each switch position according to the table.
3.
If the continuity is not as specified,
replace the ignition switch
(B).
4.
All Removed Parts - Install
1.