Measure the clearance between the select arm (A) and the interlock (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.
Standard:
0.01?0.21 mm (0.001?0.008 in)
Service Limit:
0.21 mm (0.008 in)
2.
Measure the width of the select arm.
If the width is not within the standard, replace the change lever assembly.
If the width is within the standard, replace the interlock.