Select Arm Clearance Inspection
1. Select Arm Clearance - Inspect

1.
Measure the clearance between the select arm (A) and the interlock (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.

Standard:
 
0.05?0.25 mm (0.002?0.009 in)
Service Limit:
 
0.25 mm (0.009 in)





2.
Measure the width of the select arm.

If the width is not within the standard, replace the select arm.
If the width is within the standard, replace the interlock.

Standard:
 
12.9?13.0 mm (0.508?0.512 in)