Mis-Fuel Inhibit Device Removal and Installation
Special Tools Required
Image Description/Tool Number
14219090.png Capless Wrench 07AAF-TBAA100
14219091.png Capless Flapper Retainer 07AAF-TBAA200
14219092.png Capless Pick 07AAF-TBAA300

Flammable - Keep Fire Away

NOTE: Refer to the Fuel and Emissions Systems Service Precautions before disconnecting the fuel line.

2. Mis-Fuel Inhibit Device - Remove



1.
Break the six lock tabs (A).

2.
Pry up the lock tab (B), then remove the mis-fuel inhibit device (C).

NOTE: Never reuse the mis-fuel inhibit device.

3. Main Flap Unit/Flow Guide Assembly - Remove (If Necessary)

1.
Set the capless wrench and slightly turn the main flap unit/flow guide assembly (A) counterclockwise.

NOTE:
Depending on the emission type, the main flap unit and wrench may be positioned in either direction as shown (B).
The main flap unit may move only a small amount. This is normal.





2.
Remove the capless wrench and install the capless flapper retainer onto the main flap unit/flow guide assembly (A) as shown to keep the flap open.





3.
Insert the capless pick under the lock tab (A) and release the lock by turning the pick counterclockwise.

NOTE: The lock tab is unlocked when it folds inside the filler neck opening.





4.
Set the capless wrench onto the main flap unit/flow guide assembly (A) as shown.

NOTE: It may be necessary to move the flapper retainer slightly to install the capless wrench.


5.
Turn the capless wrench clockwise until it stops, then remove it.

NOTE: If the lock tab was disengaged properly, the main flap unit/flow guide assembly should turn easily. If you feel resistance, remove the capless wrench and confirm that the lock tab was disengaged.


Flammable - Keep Fire Away

NOTE: Refer to the Fuel and Emissions Systems Service Precautions before disconnecting the fuel line.

1. Main Flap Unit/Flow Guide Assembly - Install (If Necessary)

1.
Position the new main flap unit/flow guide assembly (A) onto the filler neck (B) with the top arrow (C) at the 1 o'clock position.





2.
Install the main flap unit/flow guide assembly (A) by doing the following:

Set the capless wrench onto the main flap unit/flow guide assembly.
NOTE: Depending on the emission type, the main flap unit and wrench may be positioned in either direction as shown (B).
While pressing down on the capless wrench, turn the capless wrench counterclockwise until you hear a click. The arrow on the main flap unit/flow guide assembly should face up.
Slightly turn the capless wrench clockwise to confirm that the lock tab is engaged. The main flap unit/flow guide assembly should not turn.

2. Mis-Fuel Inhibit Device - Install

1.
Install the new mis-fuel inhibit device (A).

NOTE: Confirm the lock tabs (B) are engaged.