Change Lever Clearance Inspection
1. Change Lever Clearance - Inspect

1.
Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance exceeds the service limit, replace the change lever assembly.

Standard:
0.05?0.25 mm
(0.002?0.009 in)
Service Limit:
0.25 mm (0.009 in)