Recirculation Control Motor Removal and Installation

NOTE: Set the FRESH position before removing the recirculation control motor.

1. Blower Unit - Remove


2. Recirculation Control Motor - Remove

Remove the recirculation control motor (A).


1. Recirculation Control Motor - Install


1.
Make sure the recirculation door and linkage move smoothly.

2.
Align the position of the damper lever pins (A), then install the recirculation control motor (B).

NOTE: Make sure the damper lever pins in the motor lever are visible through the holes.

3.
After installation, make sure the motor runs smoothly.

2. Blower Unit - Install