Install the parts in the reverse order of removal.
1.
LKAS Switch - Test
1.
Measure the resistance between the LKAS switch 12P connector terminals No. 3 and No. 4 according to the table.
If there is no resistance in one or more positions, replace the LKAS switch.
Position
Resistance
OFF (RELEASE)
About 2.2 k?
ON (PRESSED)
About 60 ?
2.
Check the LED for illumination by applying power and ground to the terminals according to the table.
NOTE: Important operating characteristic; diode bias cause a diode to fully conduct electricity in one direction (forward), while not at all in the opposite direction (reverse).
If the results are not as specified, replace the LKAS switch.